CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
1000.0 AC SINGLE LOCATION AND 1000.0 DC SINGLE LOCATION |
BBRJ |
SPECIAL HANDLING FEATURE |
MAGNETIC |
FREQ |
FREQUENCY IN HERTZ |
60.0 SINGLE LOCATION |
BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
250.0 AC SINGLE LOCATION AND 50.0 DC SINGLE LOCATION |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
SHOCK RESISTANT AND MOISTURE RESISTANT AND VIBRATION RESISTANT AND SALT SPRAY PROOF |
CPRZ |
AUXILIARY SWITCH FUNCTION AND QUANTITY |
1 ALARM |
AAQL |
BODY STYLE |
SINGLE POLE TYPE |
CSWP |
SWITCH VOLTAGE RATING AND TYPE IN VOLTS |
115.0 AC AND 50.0 DC |
AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
TTQY |
TERMINAL TYPE AND QUANTITY |
2 THREADED STUD |
CSSX |
SWITCH CURRENT RATING AND TYPE IN AMPS |
5.0 AC AND 1.0 DC |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP SINGLE LOCATION |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC SINGLE LOCATION |
ADAQ |
BODY LENGTH |
2.485 INCHES MINIMUM AND 2.515 INCHES MAXIMUM |
AEGJ |
SWITCH CONTACT ARRANGEMENT |
SINGLE POLE, DOUBLE THROW |
TEST |
TEST DATA DOCUMENT |
05869-711570 DRAWING |
CQSM |
SWITCH LOCATION AND POSITION DESIGNATION |
INTERNAL AT POLE ONE |
AJEC |
BOSS HEIGHT |
0.125 INCHES MINIMUM AND 0.155 INCHES MAXIMUM |
ADTV |
CASE MATERIAL |
PLASTIC |
AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.047 INCHES MINIMUM AND 2.077 INCHES MAXIMUM |
AKPX |
POLE QUANTITY |
1 |
CPRQ |
RESET METHOD |
MANUAL |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.775 INCHES MINIMUM AND 2.955 INCHES MAXIMUM |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 THREADED HOLE |
THSD |
THREAD SERIES DESIGNATOR |
UNC |
CRTK |
SWITCH TERMINAL TYPE |
TAB, SOLDER LUG |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.925 INCHES MINIMUM AND 1.955 INCHES MAXIMUM |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
3.0 AMPERES AC SINGLE LOCATION AND 3.0 AMPERES DC SINGLE LOCATION |
APNQ |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
PKWT |
UNPACKAGED UNIT WEIGHT |
0.312 POUNDS |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
3.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 10.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE ONE |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
CMLP |
THREAD QUANTITY PER INCH |
32 |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
ADAT |
BODY WIDTH |
0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 SINGLE LOCATION |
CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |