Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
788C689H25 97942 A 7 2 A TX
SM333-3-5-230VAC400C1 74193 H 5 9 E TX
79-146-25 74193 H 3 9 A TX

CAGE Information

Code Company
74193 EATON CORP HEINEMANN PRODUCTS COMMER
97942 NORTHROP GRUMMAN SYSTEMS CORPORATION

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
FREQ FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
BBRJ SPECIAL HANDLING FEATURE MAGNETIC
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CPRX ACTUATOR POSITION DESIGNATION AT POLE TWO
AKPX POLE QUANTITY 3
THSD THREAD SERIES DESIGNATOR UNEF
AFJN FRAGILITY FACTOR MODERATELY RUGGED
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 300.0 AC ALL LOCATIONS
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 3.5 AMPERES AC ALL LOCATIONS
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.780 INCHES MAXIMUM
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND EXPLOSION RESISTANT AND HERMETICALLY SEALED
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CQJX NOMINAL THREAD SIZE 0.375 INCHES
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
CPRQ RESET METHOD MANUAL
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 1.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 13.000 MAXIMUM AT 200 PCT ALL LOCATIONS
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.875 INCHES NOMINAL
CPRP ULTIMATE TRIP TIME PER POLE IN SECONDS 8.000 MINIMUM ALL LOCATIONS AND 15.500 MAXIMUM ALL LOCATIONS
CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 230.0 AC ALL LOCATIONS
ABXD BUSHING LENGTH 0.375 INCHES NOMINAL
CPRW ACTUATOR FUNCTION TRIP-RESET
APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT
ADAQ BODY LENGTH 1.500 INCHES MAXIMUM
ADTV CASE MATERIAL METAL
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.625 INCHES NOMINAL
TEST TEST DATA DOCUMENT 97942-788C689H25 DRAWING
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING W/PANEL SEAL
AAQL BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
ADAT BODY WIDTH 1.875 INCHES MAXIMUM
CMLP THREAD QUANTITY PER INCH 32
TTQY TERMINAL TYPE AND QUANTITY 6 WIRE HOOK

Similar Parts

79-146-25 , 7914625 , 5925-00-875-0221 , 5925008750221 , 008750221 , 788C689H25 , SM333-3-5-230VAC400C1 , 79-146-25 ,