Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
NFJ632175R 21810 F 5 9 3 TX
NFJ631175R 79443 H 5 9 3 TX
1922-062 82386 A 3 2 5 TX
NFJ631175R 02201 F 5 9 3 TX
NFJ631175R 21810 F 5 9 6 TX
NFJ633175 21810 F 5 9 6 TX

CAGE Information

Code Company
02201 CHALLENGER ACQUISITION CORP ENGINEER
21810 CHALLENGER ELECTRICAL EQUIPMENT CORP
79443 FEDERAL PACIFIC ELECTRIC CO ST LOUIS
82386 JAIDINGER MFG. CO. INC. DBA JAICO PR

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 70.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 200.000 MAXIMUM AT 200 PCT ALL LOCATIONS
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE
FREQ FREQUENCY IN HERTZ 60.0 ALL LOCATIONS
ADAU BODY HEIGHT 4.375 INCHES NOMINAL
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 175.0 AMPERES AC ALL LOCATIONS
AKPX POLE QUANTITY 3
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 7.250 INCHES NOMINAL
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 15000.0 AC ALL LOCATIONS
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
AJEC BOSS HEIGHT 0.250 INCHES NOMINAL
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 1.375 INCHES NOMINAL
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 1.375 INCHES NOMINAL
ADTV CASE MATERIAL PLASTIC
CPRQ RESET METHOD MANUAL
ADAQ BODY LENGTH 9.500 INCHES NOMINAL
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.190 INCHES NOMINAL
TTQY TERMINAL TYPE AND QUANTITY 6 COMPRESSION
CPRJ TRIP RELEASE METHOD THERMAL-MAGNETIC ALL LOCATIONS
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
CPRW ACTUATOR FUNCTION TRIP-RESET
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 ROTARY
AAQL BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 600.0 AC ALL LOCATIONS
CRCF TRIP RELEASE AMBIENT TEMP RATING 40.0 DEG CELSIUS MAXIMUM ALL LOCATIONS
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 8.000 INCHES NOMINAL
ADAT BODY WIDTH 4.125 INCHES NOMINAL