CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
APL-1111-20509-1 81541 A 5 2 E TX
6403492-1 55974 A 3 2 A TX

CAGE Information

Code Company
55974 HONEYWELL INTL INC DEFENSE AVIONICS
81541 SENSATA TECHNOLOGIES MARYLAND INC

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.700 MINIMUM AT 200 PCT THIRD LOCATION AND 10.000 MAXIMUM AT 200 PCT THIRD LOCATION
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS PROOF
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 5.0 AMPERES AC SECOND LOCATION
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
AGAV END ITEM IDENTIFICATION 4920-01-111-2981
AJEC BOSS HEIGHT 0.150 INCHES NOMINAL
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 30.0 AMPERES DC FOURTH LOCATION
AKPX POLE QUANTITY 4
TTQY TERMINAL TYPE AND QUANTITY 8 THREADED STUD
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 2.000 MINIMUM AT 200 PCT SECOND LOCATION AND 22.000 MAXIMUM AT 200 PCT SECOND LOCATION
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.475 INCHES MAXIMUM
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 4 TOGGLE
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 2.000 MINIMUM AT 200 PCT FIRST LOCATION AND 22.000 MAXIMUM AT 200 PCT FIRST LOCATION
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.062 INCHES NOMINAL
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 30.0 AMPERES DC THIRD LOCATION
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC SECOND LOCATION
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 32.0 DC FOURTH LOCATION
CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, THREE, AND FOUR LINKED
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.750 INCHES NOMINAL
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 2000.0 DC FOURTH LOCATION
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 32.0 DC THIRD LOCATION
ADTV CASE MATERIAL PLASTIC
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC FIRST LOCATION
AXHR MOUNTING FACILITY TYPE AND QUANTITY 8 THREADED HOLE
CPRQ RESET METHOD MANUAL
FREQ FREQUENCY IN HERTZ 50.0 SECOND LOCATION OR 60.0 SECOND LOCATION
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 2000.0 DC THIRD LOCATION
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.700 MINIMUM AT 200 PCT FOURTH LOCATION AND 10.000 MAXIMUM AT 200 PCT FOURTH LOCATION
THSD THREAD SERIES DESIGNATOR UNC
CPRJ TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
ADAT BODY WIDTH 3.030 INCHES NOMINAL
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
CPRW ACTUATOR FUNCTION TRIP-RESET
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC SECOND LOCATION
CPRX ACTUATOR POSITION DESIGNATION AT EACH POLE
AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
CBBL FEATURES PROVIDED HIGH INRUSH PROTECTION
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
ADAQ BODY LENGTH 2.490 INCHES NOMINAL
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.940 INCHES NOMINAL
CMLP THREAD QUANTITY PER INCH 32
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 5.0 AMPERES AC FIRST LOCATION
FREQ FREQUENCY IN HERTZ 50.0 FIRST LOCATION OR 60.0 FIRST LOCATION
CQJX NOMINAL THREAD SIZE 0.138 INCHES
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.750 INCHES NOMINAL
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC FIRST LOCATION