Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
1213P35 80020 A 3 2 X XX
9311-35A 56365 A 5 9 5 TX
AN3161P35 88044 M 5 2 X XX
D6751-2-35 82647 A 5 9 5 9Z
MILC7079 81349 M 4 1 X XX
612758-7 98897 A 3 2 X XX

CAGE Information

Code Company
56365 SCHNEIDER ELECTRIC USA INC. DBA SCHN
80020 NAVAL AIR WARFARE CENTER AIRCRAFT DI
88044 AERONAUTICAL STANDARDS GROUP DEPT OF
82647 SENSATA TECHNOLOGIES INC
81349 MILITARY SPECIFICATIONS PROMULGATED
98897 LOCKHEED MARTIN CORPORATION DBA LOCK

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
TTQY TERMINAL TYPE AND QUANTITY 2 SCREW
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 138.0 SINGLE LOCATION
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 1.843 INCHES NOMINAL
AAQL BODY STYLE SINGLE POLE TYPE
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 30.0 AC SINGLE LOCATION AND 30.0 DC SINGLE LOCATION
ADAT BODY WIDTH 0.750 INCHES NOMINAL
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 35.0 AMPERES AC SINGLE LOCATION AND 35.0 AMPERES DC SINGLE LOCATION
CPRQ RESET METHOD AUTOMATIC
CRCF TRIP RELEASE AMBIENT TEMP RATING 25.0 DEG CELSIUS MAXIMUM SINGLE LOCATION
ADTV CASE MATERIAL PLASTIC
AKPX POLE QUANTITY 1
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.000 INCHES NOMINAL
THSD THREAD SERIES DESIGNATOR UNC
CPRJ TRIP RELEASE METHOD THERMAL SINGLE LOCATION
CPRW ACTUATOR FUNCTION TRIP W/SEPARATE RESET
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.125 INCHES NOMINAL
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 2500.0 AC SINGLE LOCATION AND 2500.0 DC SINGLE LOCATION
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 55.000 NOMINAL AT 200 PCT SINGLE LOCATION
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 PUSH-PULL
ABXD BUSHING LENGTH 0.125 INCHES NOMINAL
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED BUSHING
CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE
CMLP THREAD QUANTITY PER INCH 32
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED DUSTPROOF
ADAQ BODY LENGTH 2.187 INCHES NOMINAL
CQJX NOMINAL THREAD SIZE 0.138 INCHES

Similar Parts

9311-35A , 931135A , 5925-00-175-5222 , 5925001755222 , 001755222 , 1213P35 , 9311-35A , AN3161P35 , D6751-2-35 , MILC7079 , 612758-7 ,