National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
Reference/Part Number
CAGE Information
Code |
Company |
19207 |
U S ARMY TANK AUTOMOTIVE COMMAND AMS |
82647 |
SENSATA TECHNOLOGIES INC |
81349 |
MILITARY SPECIFICATIONS PROMULGATED |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
ADAT |
BODY WIDTH |
1.188 INCHES NOMINAL |
AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
1.574 INCHES NOMINAL |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.844 INCHES NOMINAL |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
AAQL |
BODY STYLE |
SINGLE POLE TYPE |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
DUSTPROOF AND CORROSION RESISTANT AND FUNGUS RESISTANT |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP SINGLE LOCATION |
CPRQ |
RESET METHOD |
AUTOMATIC |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
130.0 SINGLE LOCATION |
ADAQ |
BODY LENGTH |
1.891 INCHES NOMINAL |
ADTV |
CASE MATERIAL |
PLASTIC |
AKPX |
POLE QUANTITY |
1 |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
30.0 DC SINGLE LOCATION |
CPRJ |
TRIP RELEASE METHOD |
THERMAL SINGLE LOCATION |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
15.0 AMPERES DC SINGLE LOCATION |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
50.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
TTQY |
TERMINAL TYPE AND QUANTITY |
2 QUICK DISCONNECT, FEMALE |
AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.174 INCHES NOMINAL |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
600.0 DC SINGLE LOCATION |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
CRCF |
TRIP RELEASE AMBIENT TEMP RATING |
25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
ADAU |
BODY HEIGHT |
1.407 INCHES NOMINAL |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 UNTHREADED HOLE |
Similar Parts