National Stock Number (NSN) Output Data
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
ATB22100NS | 24446 | A | C | 1 | 6 | TX | AF | |
711507-11 | 05869 | A | 3 | 2 | A | TX | ||
507-250-101 | 79405 | H | 5 | 9 | 6 | TX | ||
105-250-101 | 79405 | H | 5 | 9 | E | TX | ||
507-250-101 | 77342 | A | 5 | 9 | E | TX | ||
ATB22100NS | 60969 | A | C | 1 | 6 | TX | AF | |
260-4778-000 | 13499 | A | 5 | 9 | 5 | TX | ||
MS25005-50 | 96906 | M | 5 | 9 | E | TX | ||
MS25017-50 | 96906 | M | 5 | 9 | E | TX |
CAGE Information
Code | Company |
---|---|
05869 | RAYTHEON COMPANY DBA RAYTHEON |
24446 | GENERAL ELECTRIC CO |
79405 | WOOD ELECTRIC OPERATIONS POTTER AND |
77342 | TYCO ELECTRONICS CORPORATION |
60969 | GENERAL ELECTRIC CO ELECTRICAL DISTR |
13499 | ROCKWELL COLLINS INC. DBA GOVERNMENT |
96906 | MILITARY STANDARDS PROMULGATED BY MI |
Federal Supply Class
Title
CIRCUIT BREAKERS
Inclusions:
INCLUDES CIRCUIT BREAKERS AND CUTOUTS.
Exclusions:
EXCLUDES RELAYS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CQJX | NOMINAL THREAD SIZE | 0.469 INCHES |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC SINGLE LOCATION AND 32.0 DC SINGLE LOCATION |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HUMIDITY RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND VIBRATION RESISTANT |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 SINGLE LOCATION |
AAQL | BODY STYLE | SINGLE POLE TYPE |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 20.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 120.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.690 INCHES MINIMUM AND 0.710 INCHES MAXIMUM |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB W/SCREW |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
THSD | THREAD SERIES DESIGNATOR | UNS |
ADAQ | BODY LENGTH | 1.090 INCHES MAXIMUM |
PKWT | UNPACKAGED UNIT WEIGHT | 0.100 POUNDS |
ADTV | CASE MATERIAL | PLASTIC |
AKPX | POLE QUANTITY | 1 |
CPRQ | RESET METHOD | MANUAL |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.810 INCHES MAXIMUM |
CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
ABXD | BUSHING LENGTH | 0.235 INCHES MINIMUM AND 0.255 INCHES MAXIMUM |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 3000.0 AC SINGLE LOCATION AND 5000.0 DC SINGLE LOCATION |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
FREQ | FREQUENCY IN HERTZ | 400.0 SINGLE LOCATION |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
ADAT | BODY WIDTH | 0.750 INCHES MAXIMUM |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES AC SINGLE LOCATION AND 50.0 AMPERES DC SINGLE LOCATION |