NSN:
NIIN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
62-467M6 74193 H 5 1 6 TX
62-467AMG4-15-250VAC-1-60H2-1REL 74193 H 5 9 E TX
26072 28500 F 3 9 5 TX

CAGE Information

Code Company
28500 BANGOR MFG CO DIV OF APPLIED POWER I
74193 EATON CORP HEINEMANN PRODUCTS COMMER

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 4.349 INCHES MINIMUM AND 4.369 INCHES MAXIMUM
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 15.0 AMPERES AC ALL LOCATIONS
FREQ FREQUENCY IN HERTZ 60.0 ALL LOCATIONS
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
ADAU BODY HEIGHT 2.677 INCHES MINIMUM AND 2.697 INCHES MAXIMUM
CPRX ACTUATOR POSITION DESIGNATION AT POLE TWO
AKPX POLE QUANTITY 3
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 70000.000 NOMINAL AT 200 PCT ALL LOCATIONS AND 20000.000 NOMINAL AT 300 PCT ALL LOCATIONS
TTQY TERMINAL TYPE AND QUANTITY 6 THREADED STUD AND 2 WIRE LEAD
AFJN FRAGILITY FACTOR MODERATELY RUGGED
AJEC BOSS HEIGHT 0.209 INCHES MINIMUM AND 0.229 INCHES MAXIMUM
CQJX NOMINAL THREAD SIZE 0.190 INCHES
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SECOND LOCATION
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.974 INCHES MINIMUM AND 0.994 INCHES MAXIMUM
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND MOISTURE RESISTANT
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP THIRD LOCATION
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC ALL LOCATIONS
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 THREADED HOLE
ADTV CASE MATERIAL PLASTIC
CPRQ RESET METHOD MANUAL
APNQ ARC QUENCHING METHOD AIR
THSD THREAD SERIES DESIGNATOR UNF
ADAQ BODY LENGTH 5.240 INCHES MINIMUM AND 5.260 INCHES MAXIMUM
CPRJ TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
CPSM INTERNAL TRIP RELEASE CONFIGURATION RELAY TRIP FIRST LOCATION
ADAT BODY WIDTH 2.990 INCHES MINIMUM AND 3.010 INCHES MAXIMUM
CPRW ACTUATOR FUNCTION TRIP-RESET
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.302 INCHES MINIMUM AND 2.322 INCHES MAXIMUM
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC ALL LOCATIONS
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
AAQL BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
CPRP ULTIMATE TRIP TIME PER POLE IN SECONDS 10000.000 NOMINAL ALL LOCATIONS
CMLP THREAD QUANTITY PER INCH 32
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.974 INCHES MINIMUM AND 0.994 INCHES MAXIMUM