Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
91500994 F6481 A 5 2 6 ZF
205-1-1REC2-65-4-202AMO 81541 A 3 2 4 9Z

CAGE Information

Code Company
81541 SENSATA TECHNOLOGIES MARYLAND INC
F6481 THALES

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
TEST TEST DATA DOCUMENT 81541-2002 SPECIFICATION
CQQR THREAD PITCH IN MILLIMETERS 0.50
AJEC BOSS HEIGHT 0.150 INCHES NOMINAL
THSD THREAD SERIES DESIGNATOR ISO S
CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC SINGLE LOCATION
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
CPRP ULTIMATE TRIP TIME PER POLE IN SECONDS 8.000 MINIMUM SINGLE LOCATION AND 60.000 MAXIMUM SINGLE LOCATION
AAQL BODY STYLE SINGLE POLE TYPE
FREQ FREQUENCY IN HERTZ 50.0 SINGLE LOCATION OR 60.0 SINGLE LOCATION
TTQY TERMINAL TYPE AND QUANTITY 2 THREADED STUD
CSSX SWITCH CURRENT RATING AND TYPE IN AMPS 10.0 AC
CQJX NOMINAL THREAD SIZE 3.0 MILLIMETERS
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.060 INCHES NOMINAL
CQQC TRIP RELEASE DUTY CYCLE CONTINUOUS SINGLE LOCATION
CPRZ AUXILIARY SWITCH FUNCTION AND QUANTITY 1 CONTROL
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.755 INCHES NOMINAL
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 2.0 AMPERES AC SINGLE LOCATION
AEGJ SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 8.000 MINIMUM AT 125 PCT SINGLE LOCATION AND 60.000 MAXIMUM AT 125 PCT SINGLE LOCATION
CQSM SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE ONE
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC SINGLE LOCATION
ADTV CASE MATERIAL PLASTIC
AKPX POLE QUANTITY 1
CPRQ RESET METHOD MANUAL
CRTK SWITCH TERMINAL TYPE QUICK DISCONNECT, MALE
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE
CPRW ACTUATOR FUNCTION TRIP-RESET
CBBL FEATURES PROVIDED HIGH INRUSH PROTECTION
CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE
CSWP SWITCH VOLTAGE RATING AND TYPE IN VOLTS 250.0 AC
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
ADAQ BODY LENGTH 2.490 INCHES NOMINAL
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.940 INCHES NOMINAL
ADAT BODY WIDTH 0.750 INCHES MAXIMUM
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED DUSTPROOF
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 SINGLE LOCATION
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC SINGLE LOCATION

Similar Parts