Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
LS10187-1 98897 A 3 2 2 9Z

CAGE Information

Code Company
98897 LOCKHEED MARTIN CORPORATION DBA LOCK

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 2.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION
CQSM SWITCH LOCATION AND POSITION DESIGNATION EXTERNAL AT POLE ONE
CQJX NOMINAL THREAD SIZE 0.469 INCHES
CSWP SWITCH VOLTAGE RATING AND TYPE IN VOLTS 115.0 AC
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
TTQY TERMINAL TYPE AND QUANTITY 2 SCREW
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING
AAQL BODY STYLE SINGLE POLE TYPE
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.742 INCHES MINIMUM AND 0.804 INCHES MAXIMUM
FREQ FREQUENCY IN HERTZ 2000.0 SINGLE LOCATION
CPRZ AUXILIARY SWITCH FUNCTION AND QUANTITY 1 CONTROL
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.287 INCHES MINIMUM AND 1.317 INCHES MAXIMUM
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
THSD THREAD SERIES DESIGNATOR UNS
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 115.0 AC SINGLE LOCATION
AKPX POLE QUANTITY 1
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 100.0 AC SINGLE LOCATION
CPRQ RESET METHOD MANUAL
ABXD BUSHING LENGTH 0.277 INCHES MAXIMUM
CSSX SWITCH CURRENT RATING AND TYPE IN AMPS 0.5 AC
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 145.0 SINGLE LOCATION
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 0.5 AMPERES AC SINGLE LOCATION
AEGJ SWITCH CONTACT ARRANGEMENT SINGLE POLE, SINGLE THROW, NORMALLY CLOSED
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 PUSH-PULL
CPRW ACTUATOR FUNCTION TRIP-RESET
ADTV CASE MATERIAL METAL
CRTK SWITCH TERMINAL TYPE TURRET
CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED MOISTURE RESISTANT AND EXPLOSION RESISTANT AND VIBRATION RESISTANT
ZZZK SPECIFICATION/STANDARD DATA 36659-LS10187 MANUFACTURERS STANDARD
ADAT BODY WIDTH 0.531 INCHES MINIMUM AND 0.593 INCHES MAXIMUM
CPRP ULTIMATE TRIP TIME PER POLE IN SECONDS 2.000 MINIMUM SINGLE LOCATION AND 20.000 MAXIMUM SINGLE LOCATION
CMLP THREAD QUANTITY PER INCH 32
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
CRCF TRIP RELEASE AMBIENT TEMP RATING 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
ADAQ BODY LENGTH 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM

Similar Parts

LS10187-1 , LS101871 , 5925-01-205-7480 , 5925012057480 , 012057480 , LS10187-1 ,