National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
Reference/Part Number
Part Number |
CAGE |
Status |
RNCC |
RNVC |
DAC |
RNAAC |
MSDS |
SADC |
9TC20-20 |
82647 |
A |
5 |
2 |
6 |
9Z |
|
|
LS10159S20 |
98897 |
A |
3 |
2 |
4 |
9Z |
|
|
CAGE Information
Code |
Company |
82647 |
SENSATA TECHNOLOGIES INC |
98897 |
LOCKHEED MARTIN CORPORATION DBA LOCK |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
FREQ |
FREQUENCY IN HERTZ |
400.0 ALL LOCATIONS |
ADAT |
BODY WIDTH |
1.094 INCHES MAXIMUM |
CQJX |
NOMINAL THREAD SIZE |
0.469 INCHES |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
2000.0 AC ALL LOCATIONS |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
20.0 AMPERES AC ALL LOCATIONS |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 THREADED BUSHING |
AKPX |
POLE QUANTITY |
3 |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
140.0 ALL LOCATIONS |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
THSD |
THREAD SERIES DESIGNATOR |
UNS |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.673 INCHES MINIMUM AND 0.805 INCHES MAXIMUM |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY ALL LOCATIONS |
CPRQ |
RESET METHOD |
MANUAL |
ABXD |
BUSHING LENGTH |
0.219 INCHES MINIMUM AND 0.281 INCHES MAXIMUM |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 PUSH-PULL |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
ADAU |
BODY HEIGHT |
1.600 INCHES MAXIMUM |
TTQY |
TERMINAL TYPE AND QUANTITY |
6 SCREW |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
120.0 AC ALL LOCATIONS |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
ADAQ |
BODY LENGTH |
2.380 INCHES MAXIMUM |
AAQL |
BODY STYLE |
MULTIPOLE-SINGLE ACTUATOR TYPE |
CMLP |
THREAD QUANTITY PER INCH |
32 |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
2.500 MINIMUM AT 200 PCT ALL LOCATIONS AND 40.000 MAXIMUM AT 200 PCT ALL LOCATIONS |