Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
MIL-PRF-83383/2 81349 M 4 1 E ZZ
MIL-C-83383/2 81349 M 5 9 E TX
M83383/02-07 81349 M 2 2 E TX

CAGE Information

Code Company
81349 MILITARY SPECIFICATIONS PROMULGATED

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
CQTL RESET ACTUATOR VOLTAGE RATING AND TYPE IN VOLTS 115.0 AC
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 150.0 SINGLE LOCATION
CPRZ AUXILIARY SWITCH FUNCTION AND QUANTITY 1 ALARM
CSWP SWITCH VOLTAGE RATING AND TYPE IN VOLTS 115.0 AC AND 28.0 DC
ABHP OVERALL LENGTH 4.260 INCHES MAXIMUM
AFJN FRAGILITY FACTOR MODERATELY RUGGED
TTQY TERMINAL TYPE AND QUANTITY 2 THREADED STUD
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 35.0 AMPERES AC SINGLE LOCATION AND 35.0 AMPERES DC SINGLE LOCATION
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 3600.0 AC SINGLE LOCATION AND 3600.0 DC SINGLE LOCATION
CPRQ RESET METHOD ELECTRIC
AEGJ SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
ABMK OVERALL WIDTH 3.250 INCHES MAXIMUM
CQSM SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE ONE
ZZZK SPECIFICATION/STANDARD DATA 81349-MIL-C-83383/2 GOVERNMENT SPECIFICATION
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.172 INCHES NOMINAL
ADTV CASE MATERIAL PLASTIC
AKPX POLE QUANTITY 1
CRCF TRIP RELEASE AMBIENT TEMP RATING 75.0 DEG FAHRENHEIT NOMINAL SINGLE LOCATION
AAQL BODY STYLE RECTANGULAR DIMENSIONAL ENVELOPE
APNQ ARC QUENCHING METHOD AIR
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 115.0 AC SINGLE LOCATION AND 28.0 DC SINGLE LOCATION
TEST TEST DATA DOCUMENT 81349-MIL-C-83383 SPECIFICATION
CPRJ TRIP RELEASE METHOD THERMAL SINGLE LOCATION
CRTK SWITCH TERMINAL TYPE TAB, SOLDER LUG
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 16.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 55.000 MAXIMUM AT 200 PCT SINGLE LOCATION
ABKW OVERALL HEIGHT 1.200 INCHES MAXIMUM
CSSX SWITCH CURRENT RATING AND TYPE IN AMPS 3.0 AC AND 3.0 DC
FREQ FREQUENCY IN HERTZ 400.0 SINGLE LOCATION
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED DUSTPROOF
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE

Similar Parts

M83383/02-07 , M833830207 , 5925-01-254-2051 , 5925012542051 , 012542051 , MIL-PRF-83383/2 , MIL-C-83383/2 , M83383/02-07 ,