Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
JE2S-L3-A-0015-02N 81118 A 3 2 4 ZZ

CAGE Information

Code Company
81118 EATON CORPORATION DBA FLUID POWER PL

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
FREQ FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
ADAT BODY WIDTH 1.500 INCHES NOMINAL
AKPX POLE QUANTITY 2
ADAQ BODY LENGTH 2.000 INCHES NOMINAL
ADAU BODY HEIGHT 1.750 INCHES NOMINAL
FEAT SPECIAL FEATURES VENTED CASE
CPRP ULTIMATE TRIP TIME PER POLE IN SECONDS 6.000 MINIMUM ALL LOCATIONS AND 70.000 MAXIMUM ALL LOCATIONS
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 UNTHREADED HOLE
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED MOISTURE RESISTANT AND SALT WATER RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT AND FUNGUS RESISTANT AND WATER RESISTANT
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.375 INCHES NOMINAL
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 65.0 DC ALL LOCATIONS
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 15.0 AMPERES DC ALL LOCATIONS
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 6.000 MINIMUM AT 150 PCT ALL LOCATIONS AND 70.000 MAXIMUM AT 150 PCT ALL LOCATIONS
TTQY TERMINAL TYPE AND QUANTITY 4 SCREW
ADTV CASE MATERIAL PLASTIC
CPRQ RESET METHOD MANUAL
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.500 INCHES NOMINAL
CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS
ABXD BUSHING LENGTH 0.375 INCHES NOMINAL
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 150.0 ALL LOCATIONS
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 DC ALL LOCATIONS
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
AAQL BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.500 INCHES NOMINAL

Similar Parts

JE2S-L3-A-0015-02N , JE2SL3A001502N , 5925-01-509-5850 , 5925015095850 , 015095850 , JE2S-L3-A-0015-02N ,