National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
SWITCH , THERMOSTATIC
Definition:
A SWITCH THAT IS ACTUATED BY CHANGES IN AMBIENT TEMPERATURE. EXCLUDES CIRCUIT BREAKER; CONTROL, TEMPERATURE (AS MODIFIED); FUSE (AS MODIFIED); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; AND THERMOSTAT, FLOW CONTROL. SEE ALSO CONTROL, TEMPERATURE (AS MODIFIED) AND REGULATOR, TEMPERATURE (AS MODIFIED).
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
644233-2 | 98897 | A | 3 | 2 | 5 | TX | ||
17320-5-200 | 73168 | A | 5 | 9 | 5 | TX |
CAGE Information
Code | Company |
---|---|
73168 | KIDDE TECHNOLOGIES INC DBA FENWAL SA |
98897 | LOCKHEED MARTIN CORPORATION DBA LOCK |
Federal Supply Class
Title
SWITCHES
Inclusions:
INCLUDES ROTARY, KNIFE, TOGGLE, PUSH BUTTON, MERCURY, THERMOSTATIC, AND DIFFERENTIAL PRESSURE SWITCHES.
Exclusions:
EXCLUDES SWITCHGEAR.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.085 INCHES NOMINAL |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.085 INCHES NOMINAL |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET |
CQYJ | MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE |
THSD | THREAD SERIES DESIGNATOR | UNC ALL THREADED HOLE |
AAJD | THREAD CLASS | 2B ALL THREADED HOLE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL SECOND VOLTAGE |
AXGY | MOUNTING METHOD | FLANGE AND THREADED HOLE |
ABHP | OVERALL LENGTH | 5.125 INCHES NOMINAL |
STYL | STYLE DESIGNATOR | CYLINDRICAL W/FLANGE |
AWTN | OPERATING TEMP RATING | -100.0 DEG FAHRENHEIT MINIMUM AND 1500.0 DEG FAHRENHEIT MAXIMUM |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL FOURTH VOLTAGE |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 0.947 INCHES NOMINAL |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
CSCF | TERMINAL TYPE | WIRE LEAD |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
ADAV | OVERALL DIAMETER | 1.750 INCHES NOMINAL |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTYM | CONTACT ADJUSTMENT RANGE | -100.00/+300.00 ACTUATION POINT DEGREES FAHRENHEIT AND -65.00/+200.00 DEACTUATION POINT DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL FIRST VOLTAGE |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
AFDT | SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.543 INCHES NOMINAL |
ADAQ | BODY LENGTH | 3.593 INCHES NOMINAL |
CMLP | THREAD QUANTITY PER INCH | 32 ALL THREADED HOLE |
ABPM | BODY DIAMETER | 0.618 INCHES MINIMUM AND 0.625 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES ALL THREADED HOLE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL THIRD VOLTAGE |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT SHAFT AND EXTERNAL ACTUATION POINT SHAFT |
CTYX | CONTACT STIMULUS RATING | 10.00 DIFFERENTIAL POINT NOMINAL DEGREES FAHRENHEIT |