National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
SWITCH , THERMOSTATIC
Definition:
A SWITCH THAT IS ACTUATED BY CHANGES IN AMBIENT TEMPERATURE. EXCLUDES CIRCUIT BREAKER; CONTROL, TEMPERATURE (AS MODIFIED); FUSE (AS MODIFIED); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; AND THERMOSTAT, FLOW CONTROL. SEE ALSO CONTROL, TEMPERATURE (AS MODIFIED) AND REGULATOR, TEMPERATURE (AS MODIFIED).
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
MILC2174 | 81349 | M | 4 | 1 | 4 | HD | ||
MILC2212 | 81349 | M | 4 | 1 | 4 | HD | ||
222-10NH2-222317 | 19278 | A | 3 | 2 | X | XX | ||
222-10NH2-2221083 | 19278 | A | C | 1 | 6 | ZZ | AC |
CAGE Information
Code | Company |
---|---|
19278 | DETROIT SWITCH INC. |
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
SWITCHES
Inclusions:
INCLUDES ROTARY, KNIFE, TOGGLE, PUSH BUTTON, MERCURY, THERMOSTATIC, AND DIFFERENTIAL PRESSURE SWITCHES.
Exclusions:
EXCLUDES SWITCHGEAR.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AXGY | MOUNTING METHOD | INLET CONNECTION |
AEVV | BULB DIAMETER | 0.688 INCHES NOMINAL |
CTYM | CONTACT ADJUSTMENT RANGE | +150.00/+175.00 ACTUATION POINT DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
ABKW | OVERALL HEIGHT | 4.406 INCHES NOMINAL |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
CTHF | CONTACT LOAD CURRENT RATING | 13.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT KNOB |
ADAQ | BODY LENGTH | 4.782 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 6.312 INCHES NOMINAL |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE VOLTAGE |
ABHP | OVERALL LENGTH | 5.375 INCHES NOMINAL |
CTHF | CONTACT LOAD CURRENT RATING | 4.6 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
AKBY | TEMP SENSING ELEMENT TYPE | BULB |
CTHF | CONTACT LOAD CURRENT RATING | 1.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.7 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED |
CSCF | TERMINAL TYPE | TAB W/SCREW |