National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
SWITCH , THERMOSTATIC
Definition:
A SWITCH THAT IS ACTUATED BY CHANGES IN AMBIENT TEMPERATURE. EXCLUDES CIRCUIT BREAKER; CONTROL, TEMPERATURE (AS MODIFIED); FUSE (AS MODIFIED); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; AND THERMOSTAT, FLOW CONTROL. SEE ALSO CONTROL, TEMPERATURE (AS MODIFIED) AND REGULATOR, TEMPERATURE (AS MODIFIED).
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
21548-2-32-5 | 71366 | A | 3 | 2 | 5 | TX | ||
21548-2-28-5 | 71366 | A | 5 | 9 | 5 | TX | ||
21548-2-32-5 | 82647 | A | 5 | 2 | 6 | TX | ||
ST5M1600-001 | 76301 | A | 3 | 2 | 1 | TX |
CAGE Information
Code | Company |
---|---|
71366 | BUNTING BEARINGS CORP |
82647 | SENSATA TECHNOLOGIES INC |
76301 | BOEING COMPANY THE DBA BOEING |
Federal Supply Class
Title
SWITCHES
Inclusions:
INCLUDES ROTARY, KNIFE, TOGGLE, PUSH BUTTON, MERCURY, THERMOSTATIC, AND DIFFERENTIAL PRESSURE SWITCHES.
Exclusions:
EXCLUDES SWITCHGEAR.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE THREADED BUSHING |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
FREQ | FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE |
ABPM | BODY DIAMETER | 0.670 INCHES MAXIMUM |
CTHF | CONTACT LOAD CURRENT RATING | 1.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE AND 2.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE AND 500.0 MILLIAMPERES LAMP LOAD FIRST VOLTAGE |
STYL | STYLE DESIGNATOR | CYLINDRICAL W/FLANGE |
AXGY | MOUNTING METHOD | THREADED BUSHING |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SECOND VOLTAGE |
CMLP | THREAD QUANTITY PER INCH | 16 SINGLE THREADED BUSHING |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CSCF | TERMINAL TYPE | WIRE LEAD |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
AAJD | THREAD CLASS | 3A SINGLE THREADED BUSHING |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
ASDB | WIDTH ACROSS FLATS | 0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM |
AWTN | OPERATING TEMP RATING | -75.0 DEG FAHRENHEIT MINIMUM AND 500.0 DEG FAHRENHEIT MAXIMUM |
CTYX | CONTACT STIMULUS RATING | 393.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 368.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE AND 2.5 AMPERES INDUCTIVE LOAD SECOND VOLTAGE AND 1.0 AMPERES LAMP LOAD SECOND VOLTAGE |
ADAQ | BODY LENGTH | 1.000 INCHES NOMINAL |
AASA | THREAD LENGTH | 0.394 INCHES MINIMUM SINGLE THREADED BUSHING AND 0.419 INCHES MAXIMUM SINGLE THREADED BUSHING |
ABHP | OVERALL LENGTH | 1.250 INCHES NOMINAL |
CQJX | NOMINAL THREAD SIZE | 0.750 INCHES SINGLE THREADED BUSHING |