National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
SWITCH , ROTARY
Definition:
A SWITCH ACTUATED BY A DEFINITE ANGULAR ROTATION OF THE SWITCH SHAFT ABOUT ITS AXIS. FOR ITEMS HAVING RATED ACTUATION TRAVEL AND PRESSURE CHARACTERISTICS, SEE SWITCH, SENSITIVE. EXCLUDES RELAY, ROTARY; SWITCH, STEPPING; AND SWITCH, TELEPHONE (AS MODIFIED).
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
123914LK | 82121 | A | 3 | 1 | A | TX | ||
L03998 | 16236 | A | 3 | 2 | E | TX |
CAGE Information
Code | Company |
---|---|
16236 | DLA LAND AND MARITIME |
82121 | ELECTRO SWITCH CORP. DBA ELECTROSWIT |
Federal Supply Class
Title
SWITCHES
Inclusions:
INCLUDES ROTARY, KNIFE, TOGGLE, PUSH BUTTON, MERCURY, THERMOSTATIC, AND DIFFERENTIAL PRESSURE SWITCHES.
Exclusions:
EXCLUDES SWITCHGEAR.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAJD | THREAD CLASS | 2B 1ST MOUNTING FACILITY |
CMLP | THREAD QUANTITY PER INCH | 20 1ST MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 3.657 INCHES MINIMUM AND 3.719 INCHES MAXIMUM |
ABHP | OVERALL LENGTH | 10.183 INCHES NOMINAL |
CBBL | FEATURES PROVIDED | ACTUATOR KNOB AND DUMMY SECTION |
ABMK | OVERALL WIDTH | 4.375 INCHES NOMINAL |
CQMK | CONTACT VOLTAGE RATING IN VOLTS | 500.0 AC AT SEA LEVEL |
AJZE | SWITCH CONTACT BASIC DESIGN | NONPILE-UP NONSYMMETRICAL |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES 1ST MOUNTING FACILITY |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.312 INCHES NOMINAL 2ND MOUNTING FACILITY |
CTHF | CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD HIGHEST DC VOLTAGE RATING AT SEA LEVEL |
CQMK | CONTACT VOLTAGE RATING IN VOLTS | 250.0 HIGHEST DC VOLTAGE RATING AT SEA LEVEL |
ALAQ | MOUNTING FACILITY CIRCLE RADIUS | 1.609 INCHES NOMINAL 1ST MOUNTING FACILITY |
AXGY | MOUNTING METHOD | BRACKET 2ND MOUNTING FACILITY AND UNTHREADED HOLE 2ND MOUNTING FACILITY |
CQMK | CONTACT VOLTAGE RATING IN VOLTS | 120.0 LOWEST DC VOLTAGE RATING AT SEA LEVEL |
CRJH | SWITCH ACTUATOR INDEXING POSITION QUANTITY | 2 SINGLE ACTUATOR |
AXGY | MOUNTING METHOD | BRACKET 1ST MOUNTING FACILITY AND THREADED HOLE 1ST MOUNTING FACILITY |
CTHF | CONTACT LOAD CURRENT RATING | 30.0 AMPERES RESISTIVE LOAD AC AT SEA LEVEL |
STYL | STYLE DESIGNATOR | TAP, CIRCUIT SELECTOR |
THSD | THREAD SERIES DESIGNATOR | UNC 1ST MOUNTING FACILITY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 3.812 INCHES NOMINAL 2ND MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | FOUR POSITION CIRCULAR 1ST MOUNTING FACILITY |
CTHF | CONTACT LOAD CURRENT RATING | 30.0 AMPERES RESISTIVE LOAD LOWEST DC VOLTAGE RATING AT SEA LEVEL AND 25.0 AMPERES INDUCTIVE LOAD LOWEST DC VOLTAGE RATING AT SEA LEVEL |
CTDN | SWITCH ACTUATOR STOP DEVICE TYPE | FIXED STOP SINGLE ACTUATOR |
CSLC | SWITCH ACTUATOR POSITIONING INCREMENT | 90.0 DEGREES SINGLE ACTUATOR |
FEAT | SPECIAL FEATURES | ITEM MUST COMPLY WITH REQUIREMENTS OF DESC PRODUCTION STANDARD NO. L03998; FOR NAVY NUCLEAR PROPULSION PLANT PRODUCTS ONLY |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE 2ND MOUNTING FACILITY |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | SHOCK RESISTANT AND VIBRATION RESISTANT |
CSCF | TERMINAL TYPE | TAB W/SCREW |