National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
SWITCH , PRESSURE
Definition:
A SWITCH WHICH IS ACTUATED BY CHANGES IN PRESSURE OF ANY GAS OR LIQUID OR BY CHANGES IN A VACUUM ACTING UPON ITS SENSING ELEMENT. EXCLUDES BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; AND SWITCH, SENSITIVE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
P74DA-9600 | 92578 | A | 3 | 2 | 4 | 9Z |
CAGE Information
Code | Company |
---|---|
92578 | JOHNSON CONTROLS INC CONTROL PRODUCT |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CTYX | CONTACT STIMULUS RATING | 20.00 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH AND 15.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH AND 5.00 DIFFERENTIAL POINT NOMINAL POUNDS PER SQUARE INCH |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET |
AXGY | MOUNTING METHOD | BRACKET |
CSCF | TERMINAL TYPE | SCREW |
CQGB | CONTACT ACTION STIMULUS | DECREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
MEDA | MEDIA FOR WHICH DESIGNED | LIQUID |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT POINTER WITH SCALE AND EXTERNAL DEACTUATION POINT POINTER WITH SCALE |
CTYM | CONTACT ADJUSTMENT RANGE | +8.00/+60.00 ACTUATION POINT POUNDS PER SQUARE INCH AND +8.00/+60.00 DEACTUATION POINT POUNDS PER SQUARE INCH |
AJZC | PRESSURE SWITCH TYPE | DIFFERENTIAL |