National Stock Number (NSN) Output Data
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
1600390 | 50019 | F | 5 | 9 | 1 | CX | ||
CDM5 | 73631 | A | 3 | 2 | 1 | CX |
CAGE Information
Code | Company |
---|---|
50019 | READY POWER CO THE |
73631 | POWERS HOLDINGS INC DBA CURTIS INDUS |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CQCZ | TERMINAL CONNECTING LINK QUANTITY | 5 SINGLE |
CQCZ | TERMINAL CONNECTING LINK QUANTITY | 5 SINGLE |
AMPS | CURRENT RATING IN AMPS | 30.0 |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 1.250 INCHES |
CWLN | TERMINAL DESIGN | LINKED NONFEEDTHRU |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 SLOT |
ABCS | TERMINAL ROW QUANTITY | 2 |
AAQX | MOUNTING SLOT WIDTH | 0.219 INCHES |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
CSCR | TERMINAL CONNECTING LINK TYPE | 1 SINGLE |
AAQW | MOUNTING SLOT LENGTH | 0.375 INCHES |
ABGQ | BOARD OVERALL HEIGHT | 1.250 INCHES |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.875 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.250 INCHES |
ABGN | BOARD OVERALL LENGTH | 4.375 INCHES |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.547 INCHES |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 1.000 INCHES |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.500 INCHES |
CRNL | NONFEEDTHRU TERMINAL TYPE | 859 SINGLE |
ABGP | BOARD OVERALL WIDTH | 2.000 INCHES |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.250 INCHES |
ABCX | BOARD CONSTRUCTION | HOLLOW CONSTRUCTION WITHOUT INSULATED STRIP |
MATT | MATERIAL | PLASTIC PHENOLIC BOARD |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 5 SINGLE |
ABGS | BASE THICKNESS | 0.500 INCHES |
AAQL | BODY STYLE | BARRIER TYPE |