National Stock Number (NSN) Output Data
Definition:
AN ENCLOSURE WHICH INCLUDES, MOUNTS AND PROTECTS ONE OR MORE TERMINALS AND/OR TERMINAL BOARDS. IT IS DESIGNED FOR AND MAY INCLUDE A COVER AND SUCH ACCESSORIES AS MOUNTING HARDWARE, BRACKETS, LOCKS, AND CONDUIT FITTINGS. FOR BOXES WHICH INCLUDE COMBINATIONS OF DIFFERENT ELECTRICAL DEVICES SUCH AS TERMINALS AND/OR TERMINAL BOARDS, FUSEHOLDERS, SWITCHES, JACKS, CIRCUIT BREAKERS, CONNECTORS AND THE LIKE, SEE DISTRIBUTION BOX. FOR BOXES WHICH ARE DESIGNED TO MOUNT, BUT WHICH DO NOT INCLUDE TERMINALS AND/OR TERMINAL BOARDS, SEE JUNCTION BOX. EXCLUDES TERMINAL BOARD ASSEMBLY. SEE ALSO CHAMBER, CABLE TERMINAL; AND INTERCONNECTING CABINET.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
4-6TB24C-2 | 53711 | A | C | 1 | 5 | ZZ | AC | |
02-07-0072 | 96169 | A | 5 | 1 | 5 | HD | ||
9000S620274132R | 80064 | A | C | 1 | 5 | ZZ | AC | |
2630-102-01 ITEM 13 | 96169 | A | C | 1 | 5 | HD | AC | |
MIL-T-24558/11 | 81349 | M | 5 | 9 | 6 | CX | ||
M24558/11-523.1 | 81349 | M | 2 | 2 | 4 | CX | ||
SYM523-1 M0D | 80064 | A | 5 | 9 | 6 | HD | ||
2630-102-05B | 96169 | A | C | 1 | 5 | HD | AC | |
4049-276 ITEM 10 | 43689 | A | C | 1 | 5 | HD | AC | |
9000S6202-74132REV0TYPE4-6TB24C2 | 80064 | A | 5 | 9 | A | CX | ||
2630-102-01-05B | 96169 | A | C | 1 | 1 | ZZ | AC | |
9000S6202-74132 | 80064 | A | C | 1 | 3 | ZZ | AC | |
SYM 523.1 | 81349 | M | C | 1 | 6 | ZZ | AC | |
02-07-0072 | 96906 | M | C | 1 | 6 | ZZ | AC | |
S6202F74132TYPE | 80064 | A | C | 1 | 5 | ZZ | AC | |
MIL-DTL-24558/11 | 81349 | M | 4 | 1 | 4 | ZZ |
CAGE Information
Code | Company |
---|---|
43689 | HUNTINGTON INGALLS INCORPORATED DIV |
53711 | NAVAL SEA SYSTEMS COMMAND |
96169 | ELECTRIC BOAT CORPORATION |
80064 | NAVAL SHIP SYSTEMS COMMAND |
81349 | MILITARY SPECIFICATIONS PROMULGATED |
96906 | MILITARY STANDARDS PROMULGATED BY MI |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CCFF | TERMINAL TYPE AND QUANTITY | 96 THREADED STUD |
CCFF | TERMINAL TYPE AND QUANTITY | 96 THREADED STUD |
AXGY | MOUNTING METHOD | BRACKET WITH THREADED HOLE |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 11.438 INCHES NOMINAL |
FEAT | SPECIAL FEATURES | TYPE A COVER; 288-WIRE |
STYL | STYLE DESIGNATOR | RECTANGULAR, SURFACE MOUNTING |
ABMK | OVERALL WIDTH | 13.375 INCHES NOMINAL |
AWAZ | MOUNTING FACILITY THREAD SIZE | 0.500-13 NPT |
AWJN | UNPACKAGED UNIT WEIGHT | 24.300 POUNDS |
MATT | MATERIAL | COPPER ALLOY |
ABKW | OVERALL HEIGHT | 16.375 INCHES NOMINAL |
AESL | STANDARD MOUNTING PATTERN DESIGNATOR | 3 POINT-TRIANGULAR |
BGJD | MAIN LINE MAXIMUM DC VOLTAGE RATING IN VOLTS | 600.0 |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | SUBMERSIBLE |
ABFY | OVERALL DEPTH | 7.625 INCHES NOMINAL |
BFYC | MAIN LINE MAXIMUM CURRENT RATING IN AMPS | 30.0 |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 9.250 INCHES NOMINAL |