National Stock Number (NSN) Output Data
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
605-2502-2 | 83330 | A | 5 | 9 | 4 | CX | ||
605-GP-2502-02 | 26405 | A | 3 | 2 | 4 | CX | ||
11291974-4 | 17773 | A | 5 | 2 | 1 | CX | ||
64A92C836-1 | 10001 | A | 5 | 1 | 1 | CX |
CAGE Information
Code | Company |
---|---|
10001 | NAVAIR AND NAVSEA MANAGED ORIGINAL D |
83330 | DIALIGHT CORPORATION |
26405 | MARATHON SPECIAL PRODUCTS CORPORATIO |
17773 | BALLISTIC MISSILE DEFENSE SYSTEMS CO |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 1.125 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.312 INCHES |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.375 INCHES |
CWLN | TERMINAL DESIGN | LINKED NONFEEDTHRU |
ABGS | BASE THICKNESS | 0.625 INCHES |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 2 SINGLE |
ABCS | TERMINAL ROW QUANTITY | 2 |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
CSCR | TERMINAL CONNECTING LINK TYPE | 1 SINGLE |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.875 INCHES |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.875 INCHES |
ABGN | BOARD OVERALL LENGTH | 4.000 INCHES |
CQCZ | TERMINAL CONNECTING LINK QUANTITY | 2 SINGLE |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.468 INCHES |
ABGP | BOARD OVERALL WIDTH | 2.500 INCHES |
ABGQ | BOARD OVERALL HEIGHT | 1.375 INCHES |
CRNL | NONFEEDTHRU TERMINAL TYPE | 597 SINGLE |
SFTT | SURFACE TREATMENT | NICKEL TERMINALS |
MATT | MATERIAL | PLASTIC PHENOLIC BOARD |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 1.125 INCHES |
AAMA | MOUNTING HOLE DIAMETER | 0.209 INCHES |
AAQL | BODY STYLE | BARRIER TYPE |