National Stock Number (NSN) Output Data
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
601-GP-2102-20 | 26405 | A | 3 | 2 | 5 | 48 | ||
601C2102-20 | 83330 | A | 5 | 9 | 5 | 48 | ||
533857-11 | 96214 | A | 5 | 2 | 5 | 48 |
CAGE Information
Code | Company |
---|---|
26405 | MARATHON SPECIAL PRODUCTS CORPORATIO |
83330 | DIALIGHT CORPORATION |
96214 | RAYTHEON COMPANY |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 1100.0 |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 1100.0 |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.421 INCHES |
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.500 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.156 INCHES |
CWLN | TERMINAL DESIGN | LINKED NONFEEDTHRU |
ABGS | BASE THICKNESS | 0.312 INCHES |
ABCS | TERMINAL ROW QUANTITY | 2 |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
CSCR | TERMINAL CONNECTING LINK TYPE | 1 SINGLE |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 20 SINGLE |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-M-14,TYPE CFG MIL SPEC SINGLE MATERIAL RESPONSE BOARD |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.421 INCHES |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 9.187 INCHES |
AMPS | CURRENT RATING IN AMPS | 20.0 |
ABGN | BOARD OVERALL LENGTH | 9.500 INCHES |
MATT | MATERIAL | COPPER ALLOY TERMINALS |
CQCZ | TERMINAL CONNECTING LINK QUANTITY | 20 SINGLE |
AAMA | MOUNTING HOLE DIAMETER | 0.175 INCHES |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.351 INCHES |
ABGP | BOARD OVERALL WIDTH | 1.125 INCHES |
CRNL | NONFEEDTHRU TERMINAL TYPE | 599 SINGLE |
SFTT | SURFACE TREATMENT | NICKEL TERMINALS |
ABGQ | BOARD OVERALL HEIGHT | 0.875 INCHES |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.437 INCHES |
MATT | MATERIAL | PLASTIC PHENOLIC BOARD AND CELLULOSE BOARD |
AAQL | BODY STYLE | BARRIER TYPE |