National Stock Number (NSN) Output Data
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
DRAWING 8941 MARK 40 | 0CAT4 | A | D | 9 | 2 | ZZ | ||
IKU4S | 0CAT4 | A | 3 | 2 | 4 | ZZ |
CAGE Information
Code | Company |
---|---|
0CAT4 | POINT EIGHT POWER INC. |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.750 INCHES |
MATT | MATERIAL | PLASTIC BOARD |
ABCS | TERMINAL ROW QUANTITY | 2 |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.840 INCHES |
ABGQ | BOARD OVERALL HEIGHT | 1.250 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.185 INCHES |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 1.000 INCHES |
MATT | MATERIAL | COPPER ALLOY TERMINALS |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.880 INCHES |
ABGP | BOARD OVERALL WIDTH | 2.000 INCHES |
AGAV | END ITEM IDENTIFICATION | SWITCHBOARD, ELECTRIC POWER GENERATION SYSTEM |
AMPS | CURRENT RATING IN AMPS | 50.0 |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.620 INCHES |
ABGN | BOARD OVERALL LENGTH | 3.250 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 FLAT BASE |
ABGS | BASE THICKNESS | 0.500 INCHES |
AAQL | BODY STYLE | BARRIER TYPE |