National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
BR7X300D59-26V | 82050 | H | C | 1 | 6 | ZZ | AC | |
B07A912BC1-0152 | 58614 | A | 5 | 2 | 5 | ZZ | ||
B07A912BC1-0152 | 82415 | A | 5 | 9 | 5 | TX | ||
BR7X300D59-26V | 56623 | A | 5 | 2 | 1 | TX | ||
BR7X300039-26V | 82050 | H | C | 1 | 5 | ZZ | AC | |
974-0875-00 | 13499 | A | 3 | 9 | 1 | TX |
CAGE Information
Code | Company |
---|---|
13499 | ROCKWELL COLLINS INC. DBA GOVERNMENT |
82050 | ESTERLINE ELECTRONICS CORP |
58614 | TYCO ELECTRONICS CORPORATION DBA CII |
82415 | AIRPAX CORP LLC |
56623 | MICROSEMI CORP.-POWER MANAGEMENT GRO |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
AKDX | WINDING QUANTITY | 1 |
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
APCN | COIL QUANTITY | 1 |
CBBL | FEATURES PROVIDED | POLARIZED |
ABKW | OVERALL HEIGHT | 1.300 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 0.558 INCHES MINIMUM AND 0.560 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 30.0 DC |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD SINGLE MOUNTING FACILITY |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
ABHP | OVERALL LENGTH | 1.070 INCHES NOMINAL |
APNA | WINDING DC RESISTANCE RATING | 500.0 OHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD |
AYSC | PILE-UP MAIN CONTACT FORM ARRANGEMENT | 2C |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
CRXH | TIME DELAY | 0.01 SECONDS NOMINAL FIXED OPERATE AND RELEASE TIME |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.560 INCHES NOMINAL SINGLE MOUNTING FACILITY |