National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
P56A1P6AS3 | 99699 | A | 5 | 2 | 5 | TX | ||
2309605PC4 | 10001 | A | 5 | 2 | 5 | TX | ||
90320420-11 | 99699 | A | 5 | 2 | 5 | TX | ||
2380594-4 | 56232 | A | 5 | 9 | A | TX | ||
2380594A4 | 56232 | A | 5 | 9 | 5 | TX | ||
230960504 | 53711 | A | C | 1 | 6 | ZZ | AC | |
KHYX264 | 02288 | A | 5 | 2 | 5 | TX | ||
2309605-4 | 10001 | A | 3 | 2 | A | TX |
CAGE Information
Code | Company |
---|---|
02288 | ALLIED CONTROLS INC. |
99699 | DRI RELAYS INC. |
10001 | NAVAIR AND NAVSEA MANAGED ORIGINAL D |
56232 | LOCKHEED MARTIN CORPORATION DBA LOCK |
53711 | NAVAL SEA SYSTEMS COMMAND |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 50.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 50.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
AKDX | WINDING QUANTITY | 1 |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
ABKW | OVERALL HEIGHT | 0.880 INCHES MINIMUM AND 0.890 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
CQYJ | MOUNTING FACILITY PATTERN | DIAGONAL SINGLE MOUNTING FACILITY |
APCN | COIL QUANTITY | 1 |
CRXH | TIME DELAY | 0.006 SECONDS MAXIMUM FIXED RELEASE TIME |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.094 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.102 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES AC INDUCTIVE LOAD AND 500.0 MILLIAMPERES DC INDUCTIVE LOAD |
APNA | WINDING DC RESISTANCE RATING | 1.92 KILOHMS NOMINAL SINGLE WINDING |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
APNQ | ARC QUENCHING METHOD | AIR |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC RESISTIVE LOAD AND 1.0 AMPERES DC RESISTIVE LOAD |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
APNP | DUTY TYPE | CONTINUOUS |
AYSC | PILE-UP MAIN CONTACT FORM ARRANGEMENT | 2C |
ABMK | OVERALL WIDTH | 0.390 INCHES MINIMUM AND 0.400 INCHES MAXIMUM |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.120 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.130 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 1.208 INCHES MINIMUM AND 1.218 INCHES MAXIMUM |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 50.0 DC |
CBME | CUBIC MEASURE | 0.434 CUBIC INCHES |
CRXH | TIME DELAY | 0.01 SECONDS MAXIMUM FIXED OPERATE TIME |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.995 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.005 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
Similar Parts
KHYX264 ,
KHYX264 ,
5945-00-052-4177 ,
5945000524177 ,
000524177
,
P56A1P6AS3 ,
2309605PC4 ,
90320420-11 ,
2380594-4 ,
2380594A4 ,
230960504 ,
KHYX264 ,
2309605-4 ,