National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
10501991 | 56161 | A | 7 | 2 | A | TX | ||
6041H11B | 81640 | A | 5 | 9 | 5 | 9Z | ||
7673712 | 19204 | A | 3 | 2 | 1 | TX | ||
6041H11 | 81640 | A | 3 | 2 | A | TX | ||
SD130W | 74063 | A | 5 | 2 | A | ZZ |
CAGE Information
Code | Company |
---|---|
19204 | ARMY UNITED STATES DEPARTMENT OF THE |
56161 | GENERAL DYNAMICS LAND SYSTEMS CANADA |
81640 | EATON CORPORATION DBA FLUID POWER DI |
74063 | TYCO ELECTRONICS CORPORATION DBA CII |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
AKDX | WINDING QUANTITY | 1 |
ADZC | ENVIRONMENTAL PROTECTION | HUMIDITY RESISTANT AND DUSTPROOF AND SALT SPRAY RESISTANT |
APCN | COIL QUANTITY | 1 |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 AMPERES DC RESISTIVE LOAD |
ABHP | OVERALL LENGTH | 3.312 INCHES NOMINAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
ABMK | OVERALL WIDTH | 2.062 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.266 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 400.0 MILLIAMPERES DC SINGLE WINDING |
ABKW | OVERALL HEIGHT | 3.125 INCHES NOMINAL |
APNP | DUTY TYPE | CONTINUOUS |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.750 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
TTQY | TERMINAL TYPE AND QUANTITY | 4 PIN ALL FUNCTIONS |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 24.0 DC |
APNA | WINDING DC RESISTANCE RATING | 71.0 OHMS NOMINAL SINGLE WINDING |
FEAT | SPECIAL FEATURES | A. INVERTED TERMINALS |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
Similar Parts
7673712 ,
7673712 ,
5945-00-237-1713 ,
5945002371713 ,
002371713
,
10501991 ,
6041H11B ,
7673712 ,
6041H11 ,
SD130W ,