National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
650-4267 | 62143 | F | 3 | 9 | 5 | TX |
CAGE Information
Code | Company |
---|---|
62143 | NORTHERN TELECOM INC TELECOM DISTRIB |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
CQYJ | MOUNTING FACILITY PATTERN | IRREGULARLY SPACED SINGLE MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 18.0 VOLTS -80 DEG FAHRENHEIT TYPE 4F SINGLE WINDING AND 29.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.173 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APCN | COIL QUANTITY | 1 |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 300.0 MILLIAMPERES DC SINGLE WINDING |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
ABKW | OVERALL HEIGHT | 3.150 INCHES NOMINAL |
APNA | WINDING DC RESISTANCE RATING | 96.0 OHMS NOMINAL SINGLE WINDING |
ABMK | OVERALL WIDTH | 1.800 INCHES NOMINAL |
APNP | DUTY TYPE | CONTINUOUS |
ABHP | OVERALL LENGTH | 3.000 INCHES NOMINAL |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 75.0 AMPERES AC RESISTIVE LOAD AND 50.0 AMPERES DC RESISTIVE LOAD |
TTQY | TERMINAL TYPE AND QUANTITY | 4 PIN ALL FUNCTIONS |
APNQ | ARC QUENCHING METHOD | NITROGEN |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 12 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |