National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
IC5182C120A6XAAX | 03497 | A | C | 1 | 6 | ZZ | AC | |
IC5182A100A106 | 71669 | H | C | 1 | 6 | ZZ | AC | |
IC5182A100A6 | 71669 | H | C | 1 | 6 | ZZ | AC | |
157B9527PC10 | 02989 | A | 5 | 2 | A | TX | ||
IC5182A100A106 | 01526 | H | 5 | 9 | 6 | TX | ||
IC5182C120A6XAAX | 02989 | A | 3 | 2 | 6 | TX | ||
IC5182A100A6 | 02989 | A | C | 1 | 6 | ZZ | AC |
CAGE Information
Code | Company |
---|---|
01526 | GENICOM CORP |
03497 | GENERAL ELECTRIC CO OUTDOOR BREAKER |
71669 | GENERAL ELECTRIC CO SWITCHGEAR AND C |
02989 | GENERAL ELECTRIC CO GE DRIVE SYSTEMS |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.190 INCHES NOMINAL SINGLE MOUNTING FACILITY |
TTQY | TERMINAL TYPE AND QUANTITY | 10 PIN ALL FUNCTIONS |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 100.0 MILLIAMPERES AC SINGLE WINDING |
ABHP | OVERALL LENGTH | 4.250 INCHES NOMINAL |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
APCN | COIL QUANTITY | 1 |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 440.0 VOLTS -80 DEG FAHRENHEIT TYPE 4F SINGLE WINDING |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 6.180 INCHES NOMINAL |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABMK | OVERALL WIDTH | 3.180 INCHES NOMINAL |
APNP | DUTY TYPE | CONTINUOUS |
APNA | WINDING DC RESISTANCE RATING | 345.0 OHMS NOMINAL SINGLE WINDING |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 440.0 AC |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.188 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |