National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
RELAY , THERMAL
Definition:
A RELAY SWITCH WHICH IS ACTUATED BY THE EFFECT OF INTERNAL HEAT GENERATED BY THE CURRENT IN ITS ENERGIZING CIRCUIT. FOR ITEMS ACTUATED BY AMBIENT, RATHER THAN INTERNAL TEMPERATURE CHANGES, SEE SWITCH, THERMOSTATIC.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
DT5031 | 93929 | A | 3 | 2 | 3 | TX | ||
DT7031 | 93929 | A | 5 | 9 | 3 | TX |
CAGE Information
Code | Company |
---|---|
93929 | SPX CORPORATION DBA RADIODETECTION |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
ADAV | OVERALL DIAMETER | 1.281 INCHES NOMINAL |
CYCT | CONTACT MAXIMUM CURRENT RATING IN AMPS | 1.0 AC OR 0.125 DC |
CYCS | CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 250.0 AC AND 48.0 DC |
CYCU | HEATER VOLTAGE RATING IN VOLTS | 26.5 |
CYCW | DELAY TIME IN SECONDS | 45.0 FIXED OPERATE NOMINAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN |
CYCV | HEATER POWER RATING IN WATTS | 4.0 |
ABHP | OVERALL LENGTH | 2.750 INCHES NOMINAL |
APFR | CONTACT ARRANGEMENT | SINGLE POLE, SINGLE THROW, NORMALLY OPEN |
TTQY | TERMINAL TYPE AND QUANTITY | 4 PIN |