National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
6957ED31-7C | 27192 | A | 5 | 9 | E | TX | ||
6957ED31-7C | 3BFG7 | R | 5 | 2 | 6 | ZZ | ||
870-187481 PL P/N 1007177 | 74924 | A | 5 | 2 | 5 | ZZ | ||
870-194099 PL P/N 1007177 | 74924 | A | 5 | 2 | 5 | ZZ | ||
1007177 | 74924 | A | 3 | 2 | 5 | ZZ | ||
N846 | 27192 | A | 3 | 9 | E | TX |
CAGE Information
Code | Company |
---|---|
27192 | DRS POWER & CONTROL TECHNOLOGIES INC |
3BFG7 | D R S POWER & CONTROL TECHNOLOGIES I |
74924 | INDUSTRIAL ENGINEERING AND EQUIPMENT |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
APCN | COIL QUANTITY | 1 |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CRXH | TIME DELAY | 0.20 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CBME | CUBIC MEASURE | 83.644 CUBIC INCHES |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 110.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
APNQ | ARC QUENCHING METHOD | AIR |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APNP | DUTY TYPE | CONTINUOUS |
ABMK | OVERALL WIDTH | 2.875 INCHES NOMINAL |
ADTV | CASE MATERIAL | METAL |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 440.0 AC |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 15.0 AMPERES AC RESISTIVE LOAD |
ABHP | OVERALL LENGTH | 6.125 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.219 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 4.750 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 8 SCREW ALL FUNCTIONS |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |