Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
P25P44D32P112 77342 A 3 2 E TX
K55-0001-001 14304 A 5 2 5 TX

CAGE Information

Code Company
14304 HARRIS CORPORATION DBA HARRIS RF COM
77342 TYCO ELECTRONICS CORPORATION

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AFRG CONTACT MATERIAL SILVER
AKDX WINDING QUANTITY 1
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 30.0 AMPERES AC RESISTIVE LOAD
PRMT PRECIOUS MATERIAL SILVER
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
APNA WINDING DC RESISTANCE RATING 34.0 OHMS NOMINAL SINGLE WINDING
ADZC ENVIRONMENTAL PROTECTION DUSTPROOF
AFJN FRAGILITY FACTOR MODERATELY RUGGED
ABKW OVERALL HEIGHT 3.000 INCHES MAXIMUM
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY
ABMK OVERALL WIDTH 3.350 INCHES MAXIMUM
CBME CUBIC MEASURE 34.170 CUBIC INCHES
AGAV END ITEM IDENTIFICATION 1000WPWRSUP
APCN COIL QUANTITY 1
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY
TTQY TERMINAL TYPE AND QUANTITY 4 THREADED STUD ALL FUNCTIONS
PMLC PRECIOUS MATERIAL AND LOCATION CONTACTS SILVER
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY
ADTV CASE MATERIAL PLASTIC
APNQ ARC QUENCHING METHOD AIR
AKSL PURPOSE FOR WHICH DESIGNED GENERAL
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
APNP DUTY TYPE CONTINUOUS
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.152 INCHES NOMINAL SINGLE MOUNTING FACILITY
ABHP OVERALL LENGTH 3.400 INCHES MAXIMUM
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 600.0 AC
CQYJ MOUNTING FACILITY PATTERN RECTANGULAR SINGLE MOUNTING FACILITY