National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
P510-D-BB | 58657 | A | 3 | 2 | E | TX |
CAGE Information
Code | Company |
---|---|
58657 | LEACH INTERNATIONAL CORPORATION DBA |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
CBME | CUBIC MEASURE | 9.472 CUBIC INCHES |
TTQY | TERMINAL TYPE AND QUANTITY | 16 WIRE HOOK ALL FUNCTIONS |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
ABMK | OVERALL WIDTH | 2.280 INCHES MINIMUM AND 2.340 INCHES MAXIMUM |
APCN | COIL QUANTITY | 1 |
ABHP | OVERALL LENGTH | 2.470 INCHES MINIMUM AND 2.530 INCHES MAXIMUM |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.990 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 2.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
APNQ | ARC QUENCHING METHOD | AIR |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 124.0 VOLTS AC 25 DEG CELSIUS ALL WINDINGS |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.227 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.237 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
ABKW | OVERALL HEIGHT | 1.580 INCHES MINIMUM AND 1.600 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AJSS | FREQUENCY IN HERTZ | 400.0 NOMINAL |
AGAV | END ITEM IDENTIFICATION | POD TEST ST T |
APNP | DUTY TYPE | CONTINUOUS |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |