National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
719771-2 | 05869 | A | 3 | 2 | 5 | TX | ||
9207-7254 | 58657 | A | 5 | 2 | E | TX |
CAGE Information
Code | Company |
---|---|
05869 | RAYTHEON COMPANY DBA RAYTHEON |
58657 | LEACH INTERNATIONAL CORPORATION DBA |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.745 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 2.755 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
AKDX | WINDING QUANTITY | 1 |
CRXH | TIME DELAY | 0.03 SECONDS MAXIMUM FIXED OPERATE TIME |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
ABHP | OVERALL LENGTH | 3.625 INCHES MAXIMUM |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SCREW ENERGIZING ELEMENT |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.215 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.218 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 AMPERES AC MOTOR LOAD AND 100.0 AMPERES DC MOTOR LOAD |
APCN | COIL QUANTITY | 1 |
ABKW | OVERALL HEIGHT | 2.675 INCHES MAXIMUM |
CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
TTQY | TERMINAL TYPE AND QUANTITY | 8 THREADED STUD CONTACTS |
CRXH | TIME DELAY | 0.02 SECONDS MAXIMUM FIXED RELEASE TIME |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 AMPERES AC RESISTIVE LOAD AND 100.0 AMPERES DC RESISTIVE LOAD |
APNQ | ARC QUENCHING METHOD | AIR |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD |
ABMK | OVERALL WIDTH | 3.500 INCHES MAXIMUM |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 200.0 AC AND 28.0 DC |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
APNP | DUTY TYPE | CONTINUOUS |
CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.870 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.880 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 AMPERES AC INDUCTIVE LOAD AND 100.0 AMPERES DC INDUCTIVE LOAD |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |