National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
M39016/06-109L | 81349 | M | 5 | 9 | E | ZZ | ||
MIL-R-39016/06 | 81349 | M | 5 | 9 | E | ZZ | ||
MIL-PRF-39016/6 | 81349 | M | 4 | 1 | E | ZZ | ||
M39016/6-109L | 81349 | M | 2 | 2 | E | ZZ |
CAGE Information
Code | Company |
---|---|
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.200 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABMK | OVERALL WIDTH | 0.410 INCHES MAXIMUM |
APCN | COIL QUANTITY | 1 |
ABHP | OVERALL LENGTH | 0.810 INCHES MAXIMUM |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.75 AMPERES DC INDUCTIVE LOAD |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES DC RESISTIVE LOAD AND 0.3 AMPERES AC RESISTIVE LOAD |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.200 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 0.410 INCHES MAXIMUM |
TTQY | TERMINAL TYPE AND QUANTITY | 8 WIRE LEAD ALL FUNCTIONS |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
APNA | WINDING DC RESISTANCE RATING | 700.0 OHMS NOMINAL SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.16 AMPERES DC LAMP LOAD |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-39016/6-109L GOVERNMENT SPECIFICATION |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 8 PRINTED CIRCUIT TERMINAL SINGLE MOUNTING FACILITY |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-39016 SPECIFICATION |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |