National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
N346-2REV2 | 96183 | F | 3 | 9 | X | XX |
CAGE Information
Code | Company |
---|---|
96183 | MERCURY MFG CORP |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CMLP | THREAD QUANTITY PER INCH | 32 FIRST MOUNTING FACILITY |
CMLP | THREAD QUANTITY PER INCH | 32 FIRST MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 4.930 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 12 PIN ALL FUNCTIONS |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 88.0 MILLIAMPERES DC RESISTIVE LOAD |
AKDX | WINDING QUANTITY | 2 |
ABKW | OVERALL HEIGHT | 4.000 INCHES NOMINAL |
CMLP | THREAD QUANTITY PER INCH | 40 SECOND MOUNTING FACILITY |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SECOND MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY AND 2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
THSD | THREAD SERIES DESIGNATOR | UNC SECOND MOUNTING FACILITY |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 1.425 KILOHMS NOMINAL ALL WINDINGS |
AAJD | THREAD CLASS | 2B FIRST MOUNTING FACILITY |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 88.0 MILLIAMPERES AC ALL WINDINGS |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.250 INCHES NOMINAL SECOND MOUNTING FACILITY |
APNQ | ARC QUENCHING METHOD | CAPACITOR |
AAJD | THREAD CLASS | 2B SECOND MOUNTING FACILITY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED HOLE SINGLE MOUNTING FACILITY |
THSD | THREAD SERIES DESIGNATOR | UNC FIRST MOUNTING FACILITY |
APNP | DUTY TYPE | CONTINUOUS |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SECOND MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 125.0 VOLTS -80 DEG FAHRENHEIT TYPE 4F ALL WINDINGS |
AGAV | END ITEM IDENTIFICATION | TYPE NO. C-1281/U |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 125.0 DC |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES FIRST MOUNTING FACILITY |
ABMK | OVERALL WIDTH | 3.500 INCHES NOMINAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE SECOND MOUNTING FACILITY |