National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
D176867 | 64959 | R | 5 | 9 | 1 | HH | ||
7598960 | 19200 | A | 3 | 2 | 1 | HH | ||
D176867 | 06KW9 | R | 5 | 2 | 5 | ZZ |
CAGE Information
Code | Company |
---|---|
06KW9 | LUCENT TECHNOLOGIES INC DBA FEDERAL |
64959 | AMERICAN TELEPHONE AND TELEGRAPH CO |
19200 | U S ARMY ARMAMENT RESEARCH & DEVELOP |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
TTQY | TERMINAL TYPE AND QUANTITY | 6 PIN ALL FUNCTIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 6 PIN ALL FUNCTIONS |
AKDX | WINDING QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 5.7 KILOHMS MINIMUM SINGLE WINDING AND 6.3 KILOHMS MAXIMUM SINGLE WINDING |
ABMK | OVERALL WIDTH | 1.430 INCHES NOMINAL |
CQYJ | MOUNTING FACILITY PATTERN | DIAGONAL SINGLE MOUNTING FACILITY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.312 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APCN | COIL QUANTITY | 1 |
ABHP | OVERALL LENGTH | 4.590 INCHES NOMINAL |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 3.0 MILLIAMPERES DC SINGLE WINDING |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
APNQ | ARC QUENCHING METHOD | AIR |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 50.0 DC |
ABKW | OVERALL HEIGHT | 1.070 INCHES NOMINAL |
APNP | DUTY TYPE | CONTINUOUS |
AYSC | PILE-UP MAIN CONTACT FORM ARRANGEMENT | 2A |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.438 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 18.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.138 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES DC RESISTIVE LOAD |