Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
SCY13 E.C.A ETABLISSEMENT CENTRAL DES APPR

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKDX WINDING QUANTITY 1
FEAT SPECIAL FEATURES TERMINALS ASSEMBLED INTO CONNECTOR RECEPTACLE ORD PART NO. 7720490
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.281 INCHES NOMINAL SINGLE MOUNTING FACILITY
TTQY TERMINAL TYPE AND QUANTITY 3 PIN ALL FUNCTIONS
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 24.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING
APCN COIL QUANTITY 1
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CRPQ NOMINAL OPERATING CURRENT RATING AND TYPE 50.0 AMPERES DC SINGLE WINDING
ABKW OVERALL HEIGHT 2.500 INCHES NOMINAL
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 58.7 AMPERES DC RESISTIVE LOAD
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY
APNP DUTY TYPE CONTINUOUS
APNA WINDING DC RESISTANCE RATING 0.48 OHMS NOMINAL SINGLE WINDING
ABHP OVERALL LENGTH 4.750 INCHES NOMINAL
ABMK OVERALL WIDTH 4.500 INCHES NOMINAL
CQYJ MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 24.0 DC
ADZC ENVIRONMENTAL PROTECTION WATERTIGHT

Similar Parts

5945005036519 , 5945005036519 , 5945-00-503-6519 , 5945005036519 , 005036519