National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
720120-1 80249 A 5 9 5 TX
330-0244-001 97871 A 5 9 1 TX
MHL012D26-5VDC 02288 A 5 2 5 TX
8862779-1 49671 F 5 9 5 TX
E685-3-50138 50237 A 5 2 1 TX
8862779-1 02769 A 5 2 5 TX
2663281 51128 A 5 2 5 TX
2663281 30003 A 3 2 A TX

CAGE Information

Code Company
02288 ALLIED CONTROLS INC.
80249 BAE SYSTEMS INFORMATION AND ELECTRON
97871 RAYTHEON COMPANY DBA RAYTHEON DIV IN
49671 LOCKHEED MARTIN CORP LOCKHEED MARTIN
50237 CAE USA INC. DIV SIMULATOR PRODUCTS
02769 LOCKHEED MARTIN CORPORATION DBA LOCK
51128 WILLIAM S GUTTENBERG DBA WILCO ELECT
30003 NAVAL AIR SYSTEMS COMMAND

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKDX WINDING QUANTITY 1
CRPQ NOMINAL OPERATING CURRENT RATING AND TYPE 80.0 MILLIAMPERES DC SINGLE WINDING
ADAV OVERALL DIAMETER 1.040 INCHES NOMINAL
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.531 INCHES NOMINAL SINGLE MOUNTING FACILITY
APCN COIL QUANTITY 1
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.125 INCHES NOMINAL SINGLE MOUNTING FACILITY
CBBL FEATURES PROVIDED POLARIZED
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 26.5 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING
APNA WINDING DC RESISTANCE RATING 300.0 OHMS NOMINAL SINGLE WINDING
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 29.5 DC
ADZC ENVIRONMENTAL PROTECTION HERMETIC
ABHP OVERALL LENGTH 1.710 INCHES NOMINAL
APNP DUTY TYPE CONTINUOUS
TTQY TERMINAL TYPE AND QUANTITY 14 PIN ALL FUNCTIONS
CQYJ MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 2.0 AMPERES AC RESISTIVE LOAD AND 1.0 AMPERES DC RESISTIVE LOAD

Similar Parts

MHL012D26-5VDC , MHL012D265VDC , 5945-00-583-1096 , 5945005831096 , 005831096 , 720120-1 , 330-0244-001 , MHL012D26-5VDC , 8862779-1 , E685-3-50138 , 8862779-1 , 2663281 , 2663281 ,