Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
3SAE1118 03538 A 5 2 5 TX
MV7141 94696 A 5 9 5 TX
KX1-1056 58219 A 5 2 5 TX
271MS115P002 49956 A 5 9 5 TX
P26B31H6AS2 99699 A 5 2 5 TX
S271MS115P002 49956 A 5 9 6 TX
S271MS115P002 3B150 A 3 2 6 TX
BR8-600B24S7 82050 H C 1 5 ZZ AC

CAGE Information

Code Company
03538 LOCKHEED MARTIN CORPORATION DBA MS2
94696 SE RELAYS LLC MAGNECRAFT DIV SE RELA
58219 OMNTEC MFG. INC.
49956 RAYTHEON COMPANY DBA RAYTHEON
99699 DRI RELAYS INC.
3B150 RAYTHEON TECHNICAL SERVICES COMPANY
82050 ESTERLINE ELECTRONICS CORP

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKDX WINDING QUANTITY 1
AAJD THREAD CLASS 2A SINGLE MOUNTING FACILITY
CRPQ NOMINAL OPERATING CURRENT RATING AND TYPE 40.0 MILLIAMPERES DC SINGLE WINDING
THSD THREAD SERIES DESIGNATOR UNC SINGLE MOUNTING FACILITY
APCN COIL QUANTITY 1
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 0.412 INCHES NOMINAL SINGLE MOUNTING FACILITY
ABHP OVERALL LENGTH 0.790 INCHES NOMINAL
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 2.0 AMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED STUD SINGLE MOUNTING FACILITY
ADZC ENVIRONMENTAL PROTECTION HERMETIC
TTQY TERMINAL TYPE AND QUANTITY 8 PIN ALL FUNCTIONS
APNA WINDING DC RESISTANCE RATING 600.0 OHMS NOMINAL SINGLE WINDING
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 32.0 DC
APNP DUTY TYPE CONTINUOUS
CQJX NOMINAL THREAD SIZE 0.112 INCHES SINGLE MOUNTING FACILITY
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 26.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING
CQYJ MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY
ABMK OVERALL WIDTH 0.350 INCHES NOMINAL
ABKW OVERALL HEIGHT 1.370 INCHES NOMINAL

Similar Parts

3SAE1118 , 3SAE1118 , 5945-00-814-6149 , 5945008146149 , 008146149 , 3SAE1118 , MV7141 , KX1-1056 , 271MS115P002 , P26B31H6AS2 , S271MS115P002 , S271MS115P002 , BR8-600B24S7 ,