Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
KHJX39 02288 A 3 2 4 ZF

CAGE Information

Code Company
02288 ALLIED CONTROLS INC.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 28.0 DC
AKDX WINDING QUANTITY 1
ABHP OVERALL LENGTH 1.180 INCHES NOMINAL
ABKW OVERALL HEIGHT 1.060 INCHES NOMINAL
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 2.00 AMPERES DC INDUCTIVE LOAD
APCN COIL QUANTITY 1
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY
ABMK OVERALL WIDTH 0.400 INCHES NOMINAL
APNA WINDING DC RESISTANCE RATING 675.0 OHMS NOMINAL SINGLE WINDING
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 0.125 INCHES NOMINAL SINGLE MOUNTING FACILITY
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 14.5 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING
ADZC ENVIRONMENTAL PROTECTION HERMETIC
APNP DUTY TYPE CONTINUOUS
AYSC PILE-UP MAIN CONTACT FORM ARRANGEMENT 2C
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.096 INCHES NOMINAL SINGLE MOUNTING FACILITY
CQYJ MOUNTING FACILITY PATTERN RECTANGULAR SINGLE MOUNTING FACILITY

Similar Parts

KHJX39 , KHJX39 , 5945-00-860-7977 , 5945008607977 , 008607977 , KHJX39 ,