National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
M250X2-7466 | 58657 | A | 3 | 2 | 5 | KE | ||
EX2A005 | 58657 | A | 5 | 2 | 6 | TX |
CAGE Information
Code | Company |
---|---|
58657 | LEACH INTERNATIONAL CORPORATION DBA |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
ABKW | OVERALL HEIGHT | 0.410 INCHES NOMINAL |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 29.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
APCN | COIL QUANTITY | 1 |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.120 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CBBL | FEATURES PROVIDED | POLARIZED |
APNA | WINDING DC RESISTANCE RATING | 700.0 OHMS NOMINAL SINGLE WINDING |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 29.0 DC |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES DC RESISTIVE LOAD |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
ABMK | OVERALL WIDTH | 0.410 INCHES NOMINAL |
ABHP | OVERALL LENGTH | 0.810 INCHES NOMINAL |
APNP | DUTY TYPE | CONTINUOUS |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |