National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
M83536/10 | 81349 | M | E | 8 | E | ZZ | ||
M83536/10-022L | 81349 | M | E | 8 | E | ZZ | ||
MIL-R-83536/10 | 81349 | M | 5 | 9 | E | ZZ | ||
MIL-PRF-83536/10 | 81349 | M | 4 | 1 | E | ZZ | ||
MS27401-44X | 96906 | M | 5 | 9 | E | TX | ||
M83536/10-022M | 81349 | M | 2 | 2 | E | ZZ |
CAGE Information
Code | Company |
---|---|
81349 | MILITARY SPECIFICATIONS PROMULGATED |
96906 | MILITARY STANDARDS PROMULGATED BY MI |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC LAMP LOAD AND 2.0 AMPERES DC LAMP LOAD |
AKDX | WINDING QUANTITY | 1 |
ZZZK | SPECIFICATION/STANDARD DATA | 81349--83536/10 GOVERNMENT SPECIFICATION |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
ABHP | OVERALL LENGTH | 1.025 INCHES MAXIMUM |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 110.0 MILLIAMPERES DC SINGLE WINDING |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
APNA | WINDING DC RESISTANCE RATING | 320.0 OHMS NOMINAL SINGLE WINDING |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-83536 SPECIFICATION |
ABKW | OVERALL HEIGHT | 1.010 INCHES MAXIMUM |
APCN | COIL QUANTITY | 1 |
ABMK | OVERALL WIDTH | 0.525 INCHES MAXIMUM |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
APNQ | ARC QUENCHING METHOD | AIR |
CRXH | TIME DELAY | 0.01 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 8.0 AMPERES AC INDUCTIVE LOAD AND 8.0 AMPERES DC INDUCTIVE LOAD |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
CBME | CUBIC MEASURE | 0.543 CUBIC INCHES |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 200.0 AC AND 28.0 DC |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 4.0 AMPERES AC MOTOR LOAD AND 4.0 AMPERES DC MOTOR LOAD |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
APNP | DUTY TYPE | CONTINUOUS |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
ABTD | MOUNTING SLOT WIDTH | 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
ADTV | CASE MATERIAL | METAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.421 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
FEAT | SPECIAL FEATURES | FAILURE RATE: 1.0 PERCENT PER 10,000 CYCLES |