Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
RELAY , THERMAL

Definition:

A RELAY SWITCH WHICH IS ACTUATED BY THE EFFECT OF INTERNAL HEAT GENERATED BY THE CURRENT IN ITS ENERGIZING CIRCUIT. FOR ITEMS ACTUATED BY AMBIENT, RATHER THAN INTERNAL TEMPERATURE CHANGES, SEE SWITCH, THERMOSTATIC.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
LS-6052 93929 A 3 2 4 9Z
9200-9000-060 K2516 A 5 2 2 ZK

CAGE Information

Code Company
93929 SPX CORPORATION DBA RADIODETECTION
K2516 MINISTRY OF DEFENCE NAVY SHIPS SUPPO

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CYCS CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 32.0 DC
ABKW OVERALL HEIGHT 0.875 INCHES NOMINAL
APFR CONTACT ARRANGEMENT SINGLE POLE, SINGLE THROW, NORMALLY CLOSED
CYCT CONTACT MAXIMUM CURRENT RATING IN AMPS 2.0 AC OR 1.0 DC
ADZC ENVIRONMENTAL PROTECTION SHOCK PROOF AND VIBRATION PROOF
ABHP OVERALL LENGTH 1.375 INCHES NOMINAL
CYCV HEATER POWER RATING IN WATTS 4.0
TTQY TERMINAL TYPE AND QUANTITY 7 TURRET
ABMK OVERALL WIDTH 1.000 INCHES NOMINAL
CYCU HEATER VOLTAGE RATING IN VOLTS 5.0
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE

Similar Parts

LS-6052 , LS6052 , 5945-01-323-4475 , 5945013234475 , 013234475 , LS-6052 , 9200-9000-060 ,