National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
6457158-1 | 55974 | A | 3 | 2 | A | ZZ | ||
M39016/43-070P | 81349 | M | 4 | 1 | E | ZZ |
CAGE Information
Code | Company |
---|---|
55974 | HONEYWELL INTL INC DEFENSE AVIONICS |
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC AND 115.0 AC |
APNA | WINDING DC RESISTANCE RATING | 400.0 OHMS NOMINAL SINGLE WINDING |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 9 TERMINAL SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 0.335 INCHES MAXIMUM |
APCN | COIL QUANTITY | 1 |
TTQY | TERMINAL TYPE AND QUANTITY | 9 WIRE LEAD ALL FUNCTIONS |
FEAT | SPECIAL FEATURES | FAILURE RATE 0.1 PERCENT PER 10,000 CYCLES |
CRXH | TIME DELAY | 0.007 SECONDS MAXIMUM FIXED RELEASE TIME |
APNP | DUTY TYPE | CONTINUOUS |
CRXH | TIME DELAY | 0.004 SECONDS MAXIMUM FIXED OPERATE TIME |
ABKW | OVERALL HEIGHT | 0.375 INCHES MAXIMUM |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC RESISTIVE LOAD |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
ABMK | OVERALL WIDTH | 0.335 INCHES MAXIMUM |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 9.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CBBL | FEATURES PROVIDED | COIL VOLTAGE SUPPRESSION |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 200.0 MILLIAMPERES DC INDUCTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 MILLIAMPERES DC LAMP LOAD |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |