National Stock Number (NSN) Output Data
Definition:
AN ITEM CONSISTING OF A PARTIAL TURN AS ONE OR MORE TURNS OF WIRE OR OTHER CONDUCTIVE MATERIAL WHICH CONSTITUTES ONE CONTINUOUS UNTAPPED WINDING. IT MAY BE WOUND OR FORMED IN OTHER THAN A CIRCULAR MANNER AND MAY BE SELF-SUPPORTING, REQUIRING NO COIL FORM. IT IS SPECIFICALLY DESIGNED TO FURNISH INDUCTIVE REACTANCE IN A CIRCUIT CARRYING RADIO FREQUENCY CURRENT RANGING FROM 20 KILOHERTZ (KILOCYCLES) AND ABOVE. IT MAY INCLUDE TUNING DEVICES, INTEGRAL RESISTORS AND CAPACITORS; HOWEVER, EXCLUDES FILTER (AS MODIFIED). THE COIL HAS ONLY TWO ELECTRICAL TERMINALS. FOR ITEMS HAVING TAPPED WINDING OR MORE THAN ONE WINDING - SEE TRANSFORMER, RADIO FREQUENCY. FOR COILS WOUND ON RESISTORS, WHICH ARE DESIGNED TO BE INSERTED IN THE CIRCUIT OF A RADIO FREQUENCY STAGE TO SUPPRESS HIGH FREQUENCY PARASITIC OSCILLATIONS, SEE SUPPRESSOR, PARASITIC.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
10118-20 | 59474 | F | 5 | 9 | A | TX | ||
L2088300-42 | 06845 | A | 5 | 9 | A | TX | ||
2088300-0042 | 27914 | A | 3 | 2 | A | TX | ||
2088300-0042 | 78429 | A | 5 | 2 | 5 | TX | ||
L2088300-42 | 27914 | A | 5 | 2 | A | TX | ||
2088300-42 | 27914 | A | C | 1 | 5 | ZZ | AC | |
2088300-0042 | 76493 | A | 5 | 9 | 5 | TX | ||
2088300-0042 | 99800 | A | 5 | 2 | 5 | TX |
CAGE Information
Code | Company |
---|---|
06845 | RAYTHEON COMPANY DBA RAYTHEON |
59474 | JEFFERS ELECTRONICS INC |
27914 | HONEYWELL INTERNATIONAL INC DBA HONE |
78429 | CARBON/GRAPHITE GROUP INC THE |
76493 | BELL INDUSTRIES INC J W MILLER MAGNE |
99800 | AMERICAN PRECISION INDUSTRIES INC DB |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADAQ | BODY LENGTH | 0.440 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.440 INCHES NOMINAL |
CRBZ | WINDING OPERATING CURRENT | 1.02 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE WINDING |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CRGS | DC RESISTANCE RATING IN OHMS | 0.340 SINGLE COMPONENT SINGLE WINDING |
ACYV | INDUCTANCE RATING | 3.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING |
CRHJ | QUALITY FACTOR | 50 MINIMUM SINGLE COMPONENT SINGLE WINDING |
ACZP | COIL FORM TYPE | SOLID SINGLE COMPONENT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
AFGS | MINIMUM SELF-RESONANT FREQUENCY (NON-CORE) | 80.0 MEGAHERTZ SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 120.0 DEG CELSIUS |
CRLC | FREQUENCY AT WHICH INDUCTANCE AND QUALITY FACTOR APPLIES (NON-CORE) | 10.0 MEGAHERTZ SINGLE COMPONENT SINGLE WINDING |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
ADAR | BODY OUTSIDE DIAMETER | 0.190 INCHES NOMINAL |