Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
RC8115-1C 28528 R 3 9 X XX
RC8115-1C 31550 A 5 2 5 ZZ
L18-116B 20950 A 5 9 X XX

CAGE Information

Code Company
20950 ESPEY MFG & ELECTRONICS CORP.
28528 ITT INDUSTRIES INC ITT AEROSPACE COM
31550 ITT CORPORATION DBA ITT COMMUNICATIO

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
CRBZ WINDING OPERATING CURRENT 145.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY
AKNA INCLOSURE TYPE FULLY INCLOSED
CRBZ WINDING OPERATING CURRENT 3.8 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 4TH SECONDARY
THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
ABHP OVERALL LENGTH 3.312 INCHES NOMINAL
AARG RELIABILITY INDICATOR NOT ESTABLISHED
CQJX NOMINAL THREAD SIZE 0.164 INCHES SINGLE GROUP
ADAU BODY HEIGHT 4.500 INCHES NOMINAL
CWJS WINDING OPERATING VOLTAGE 6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
AXGY MOUNTING METHOD THREADED STUD SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY
CRBZ WINDING OPERATING CURRENT 600.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY
TTQY TERMINAL TYPE AND QUANTITY 14 STANDOFF, SOLDER LUG
CWJS WINDING OPERATING VOLTAGE 5.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT 1ST SECONDARY
ABMK OVERALL WIDTH 2.812 INCHES NOMINAL
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
CMLP THREAD QUANTITY PER INCH 32 SINGLE GROUP
AAJD THREAD CLASS (NON-CORE) 2A SINGLE GROUP
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT 2ND SECONDARY
ABKW OVERALL HEIGHT 5.000 INCHES NOMINAL
CWJS WINDING OPERATING VOLTAGE 470.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CQLC WINDING TAP LOCATION (NON-CORE) MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY
CRBZ WINDING OPERATING CURRENT 3.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY
ACZB FREQUENCY RATING 60.0 HERTZ NOMINAL SINGLE COMPONENT
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT

Similar Parts

L18-116B , L18116B , 5950-00-194-6798 , 5950001946798 , 001946798 , RC8115-1C , RC8115-1C , L18-116B ,