National Stock Number (NSN) Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
S21589A | 72149 | A | 3 | 2 | 5 | TX |
CAGE Information
Code | Company |
---|---|
72149 | ELECTRONIC TRANSFORMER CORP. |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CQLC | WINDING TAP LOCATION (NON-CORE) | TAP W/O CENTER TAP SINGLE COMPONENT SINGLE SECONDARY |
CQLC | WINDING TAP LOCATION (NON-CORE) | TAP W/O CENTER TAP SINGLE COMPONENT SINGLE SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
ADAT | BODY WIDTH | 3.000 INCHES NOMINAL |
CRBZ | WINDING OPERATING CURRENT | 18.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ADAQ | BODY LENGTH | 4.500 INCHES NOMINAL |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ADAU | BODY HEIGHT | 3.875 INCHES NOMINAL |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
TTQY | TERMINAL TYPE AND QUANTITY | 5 STANDOFF INSULATOR |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 8 SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 850.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY AND 1.20 AC MINOR WET SINGLE COMPONENT SINGLE SECONDARY |
AAJD | THREAD CLASS (NON-CORE) | 2A SINGLE GROUP |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |