National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
REACTOR-TRANSFORMER
Definition:
A COMPONENT CONSISTING OF TWO OR MORE ELECTRICALLY DISTINCT ITEMS. ONE OR MORE ITEMS ARE MADE OF ONE OR MORE COILS WHICH FUNCTION AS A REACTOR; AT LEAST ONE OTHER ITEM IS MADE OF A TAPPED COIL OR TWO OR MORE COILS WHICH FUNCTION AS A TRANSFORMER. THE ITEMS MAY HAVE A COMMON CORE, BUT ARE NOT MAGNETICALLY COUPLED.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
A16805 | 00144 | A | 5 | 9 | 5 | TX | ||
S4108A | 80023 | A | 5 | 2 | 5 | TX | ||
7900088-00 | 90536 | A | 3 | 2 | A | TX |
CAGE Information
Code | Company |
---|---|
00144 | ADC TELECOMMUNICATIONS INC. DIV ADC |
80023 | HIREL SYSTEMS LLC |
90536 | LOCKHEED MARTIN CORPORATION DBA LOCK |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 12 SOLDERLESS LUG |
ABHP | OVERALL LENGTH | 4.125 INCHES MAXIMUM |
CRBZ | WINDING OPERATING CURRENT | 0.8 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT SINGLE WINDING |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
ABKW | OVERALL HEIGHT | 2.875 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.380 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.380 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACYV | INDUCTANCE RATING | 0.10 HENRY NOMINAL SINGLE COMPONENT SINGLE WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 0.020 SINGLE COMPONENT SINGLE WINDING |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ABMK | OVERALL WIDTH | 3.125 INCHES MAXIMUM |
AAJD | THREAD CLASS (NON-CORE) | 2A SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE WINDING AND 22.00 DC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE WINDING |