Follow Us on Google+

Request A Price Quote:

National Stock Number (NSN) Output Data

NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
C16769 72149 A 5 2 5 ZZ
1569243 10001 A 3 2 A TX
BTC-14462 89870 A 5 9 5 ZZ
L504000359 36090 A 5 2 5 HD

CAGE Information

Code Company
10001 NAVAIR AND NAVSEA MANAGED ORIGINAL D
72149 ELECTRONIC TRANSFORMER CORP.
89870 BERKSHIRE TRANSFORMER
36090 LOCKHEED MARTIN LIBRASCOPE CORP

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
CBME CUBIC MEASURE (NON-CORE) 16.9 CUBIC INCHES
TTQY TERMINAL TYPE AND QUANTITY 10 TURRET
TEST TEST DATA DOCUMENT 10001-1569243 DRAWING
THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.677 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.697 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
ABMK OVERALL WIDTH 2.062 INCHES MAXIMUM
CQLC WINDING TAP LOCATION (NON-CORE) TAP W/O CENTER TAP SINGLE COMPONENT 1ST SECONDARY
AEHZ MAXIMUM OPERATING TEMP 70.0 DEG CELSIUS
ABHP OVERALL LENGTH 2.312 INCHES MAXIMUM
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ACZX WINDING SHIELDING METHOD EXTERNAL INCLOSURE SINGLE COMPONENT
CQJX NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP
AKNA INCLOSURE TYPE HERMETICALLY SEALED
AXGY MOUNTING METHOD THREADED STUD SINGLE GROUP
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.427 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.447 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CQLC WINDING TAP LOCATION (NON-CORE) TAP W/O CENTER TAP SINGLE COMPONENT 2ND SECONDARY
CWJS WINDING OPERATING VOLTAGE 108.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 122.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 8.25 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY AND 12.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
AAJD THREAD CLASS (NON-CORE) 2A SINGLE GROUP
ABKW OVERALL HEIGHT 3.545 INCHES MAXIMUM
CQLC WINDING TAP LOCATION (NON-CORE) MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY
CWJS WINDING OPERATING VOLTAGE 8.25 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 12.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY

Similar Parts