National Stock Number (NSN) Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
B5562 | 03860 | A | 3 | 9 | A | TX |
CAGE Information
Code | Company |
---|---|
03860 | LAU TECHNOLOGIES DIV N/A |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND SLOT SINGLE GROUP |
ADAQ | BODY LENGTH | 2.625 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ABTD | MOUNTING SLOT WIDTH | 0.183 INCHES MINIMUM SINGLE GROUP AND 0.193 INCHES MAXIMUM SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CBME | CUBIC MEASURE (NON-CORE) | 15.5 CUBIC INCHES |
ADAU | BODY HEIGHT | 2.500 INCHES MAXIMUM |
TTQY | TERMINAL TYPE AND QUANTITY | 6 WIRE LEAD |
CRBZ | WINDING OPERATING CURRENT | 500.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 57.50 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL PRIMARY |
CBBL | FEATURES PROVIDED | W/RECTIFIER AND COLOR CODED LEAD |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.933 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.943 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ADAT | BODY WIDTH | 2.375 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.120 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.130 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE COMPONENT AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT |